SWITCH CISCO WS-C2960+48TC-S

Đánh giá: star1 star2 star3 star4 star5 | Tình trạng: Còn hàng | Lượt xem: 1130

SWITCH CISCO WS-C2960+48TC-S
- WS-C2960+48TC-S Catalyst 2960 Plus Switch
- Catalyst 2960 Plus 48 10/100 + 2 T/SFP LAN Lite

- ĐẦY ĐỦ CO-CQ

Bảo hành:
Giá bán(đã bao gồm VAT): Liên Hệ
Số lượng:
Mua ngay
Thêm vào giỏ

Yên tâm mua sắm tại Sáng Tạo

 37/4 TRẦN ĐÌNH XU, P.CẦU KHO, Q1       

           (KHÔNG CHI NHÁNH) 


yes 100% sản phẩm chính hãng

yes Giá cạnh tranh nhất thị trường

yes Giao hàng miễn phí 3km

yes Giá lẻ = Giá sỉ 


  TƯ VẤN BÁN HÀNG

Hotline: 093.848.6646 - 0896.488.339

smiley​ ​Ms.Dương  : 0909205482

smiley Ms.Mai        : 0896.488.339

smiley Ms.Mai        : 0896.466.339

smiley Ms.Lam       : 093.848.6646 

smiley​ ​Ms.Thanh   : 0976.518.679

smiley Ms.Dương  : 0913.713.339

smiley CSKH          : 028.6657.1397

mail Email : dathang.sangtao@gmail.com 

 


HỖ TRỢ KỸ THUẬT

smiley IT : 0937.399.854

smiley IT : 0798.324.324

smiley IT : 0856.329.359

smiley IT : 0909.284.074


HỖ TRỢ BẢO HÀNH

 smiley CSKH : 028.6657.1397 

 ​smiley CSKH : 0798.324.324

 

TỪ KHÓA:

Thông số kỹ thuật

SWITCH CISCO WS-C2960+48TC-S

Configurations
10/100 Ethernet Interfaces 48  
Uplink Interfaces 2 (SFP or 1000BASE-T)  
Cisco IOS Software Feature Set LAN Lite  
Available PoE Power None  
Hardware
Flash memory 64 MB  
DRAM 128 MB  
Performance and Scalability
Forwarding bandwidth 16 Gbps  
Maximum active VLANs 64  
VLAN IDs available 4K  
Maximum transmission unit (MTU) – L3 packet 9000 bytes  
Jumbo frame – Ethernet frame 9018 bytes  
Forwarding Rate: 64-Byte L3 Packets, Millions of packets per second 10.1  
Mechanical
Dimensions (H x W x D) 1.73 x 17.70 x 9.52 in (4.4 x 45.0 x 24.2 cm)  
Weight 8 lb (3.6 Kg)  
Package Weight 17.64 lb (8.0 Kg)  
Environmental Ranges
Operating temperature up to 5000 ft (1500 m) 23º to 113ºF

(-5º to 45ºC)

 
Operating temperature up to 10,000 ft (3000 m) 23º to 104ºF

(-5º to 40ºC)

 
Short-term exception at sea level* 23º to 131ºF

(-5º to 55ºC)

 
Short-term exception up to 5000 feet (1500 m)* 23º to 122ºF

(-5º to 50ºC)

 
Short-term exception up to 10,000 feet (3000 m)* 23º to 113ºF

(-5º to 45ºC)

 
Short-term exception up to 13,000 feet (4000 m)* 23º to 104ºF

(-5º to 40ºC)

 
Storage temperature up to 15,000 feet (4573 m) 23º to 158ºF

(-25º to 70ºC)

 
Operating altitude Up to 10,000 Feet

(Up to 3,000 Meters)

 
Storage altitude Up to 13,000 Feet

(Up to 4,000 Meters)

 
Operating relative humidity 10% to 95% noncondensing  
Storage relative humidity 10% to 95% noncondensing  
Sound Pressure, dBA Typical, LpAm: 33

Maximum, LpAD: 36

 
Sound Power, dbA Typical, LwA: 43

Maximum, LwAD: 46

 
MTBF in thousands of hours 623  
Connectors and Interfaces
Ethernet Interfaces
  • 10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 unshielded twisted-pair (UTP) cabling
  • 100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling
  • 1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling
  • 1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling
 
Indicator LEDs
  • Per-port status: Link integrity, disabled, activity, speed, and full duplex
  • System status, Port Status, RPS, link duplex, and link speed
 
Console Cisco Catalyst console cables:
  • CAB-CONSOLE-RJ45 Console cable 6 ft. with RJ-45
 
Power
  • The internal power supply is an auto-ranging unit and supports input voltages between 100 and 240V AC.
  • Use the supplied AC power cord to connect the AC power connector to an AC power outlet.
  • The Cisco RPS connector offers connection for an optional Cisco RPS 2300 that uses AC input and supplies DC output to the switch.
  • Only the Cisco RPS 2300 (model PWR-RPS2300) should be attached to the redundant-power-system receptacle.
 
Management and Standards Support
Management
  • BRIDGE-MIB
  • CISCO-CABLE-DIAG-MIB
  • CISCO-CDP-MIB
  • CISCO-CLUSTER-MIB
  • CISCO-CONFIG-COPY-MIB
  • CISCO-CONFIG-MAN-MIB
  • CISCO-DHCP-SNOOPING-MIB
  • CISCO-ENTITY-VENDORTYPE-OID-MIB
  • CISCO-ENVMON-MIB
  • CISCO-ERR-DISABLE-MIB
  • CISCO-FLASH-MIB
  • CISCO-FTP-CLIENT-MIB
  • CISCO-IGMP-FILTER-MIB
  • CISCO-IMAGE-MIB
  • CISCO-IP-STAT-MIB
  • CISCO-LAG-MIB
  • CISCO-MAC-NOTIFICATION-MIB
  • CISCO-MEMORY-POOL-MIB
  • CISCO-PAGP-MIB
  • CISCO-PING-MIB
  • CISCO-POE-EXTENSIONS-MIB
  • CISCO-PORT-QOS-MIB
  • CISCO-PORT-SECURITY-MIB
  • CISCO-PORT-STORM-CONTROL-MIB
  • CISCO-PRODUCTS-MIB
  • CISCO-PROCESS-MIB
  • CISCO-RTTMON-MIB
  • CISCO-SMI-MIB
  • CISCO-STP-EXTENSIONS-MIB
  • CISCO-SYSLOG-MIB
  • CISCO-TC-MIB
  • CICSO-TCP-MIB
  • CISCO-UDLDP-MIB
  • CISCO-VLAN-IFTABLE
  • RELATIONSHIP-MIB
  • CISCO-VLAN-MEMBERSHIP-MIB
  • CISCO-VTP-MIB
  • ENTITY-MIB
  • ETHERLIKE-MIB
  • IEEE8021-PAE-MIB
  • IEEE8023-LAG-MIB
  • IF-MIB
  • INET-ADDRESS-MIB
  • OLD-CISCO-CHASSIS-MIB
  • OLD-CISCO-FLASH-MIB
  • OLD-CISCO-INTERFACES-MIB
  • OLD-CISCO-IP-MIB
  • OLD-CISCO-SYS-MIB
  • OLD-CISCO-TCP-MIB
  • OLD-CISCO-TS-MIB
  • RFC1213-MIB
  • RMON-MIB
  • RMON2-MIB
  • SNMP-FRAMEWORK-MIB
  • SNMP-MPD-MIB
  • SNMP-NOTIFICATION-MIB
  • SNMP-TARGET-MIB
  • SNMPv2-MIB
  • TCP-MIB
  • UDP-MIB
  • ePM MIB
 
Standards
  • IEEE 802.1D Spanning Tree Protocol
  • IEEE 802.1p CoS Prioritization
  • IEEE 802.1Q VLAN
  • IEEE 802.1s
  • IEEE 802.1w
  • IEEE 802.1X
  • IEEE 802.1ab (LLDP)
  • IEEE 802.3ad
  • IEEE 802.3af
  • IEEE 802.3ah (100BASE-X single/multimode fiber only)
  • IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports
  • IEEE 802.3 10BASE-T
  • IEEE 802.3u 100BASE-TX
  • IEEE 802.3ab 1000BASE-T
  • IEEE 802.3z 1000BASE-X
  • RMON I and II standards
  • SNMP v1, v2c, and v3
 
RFC compliance
  • RFC 768 – UDP
  • RFC 783 – TFTP
  • RFC 791 – IP
  • RFC 792 – ICMP
  • RFC 793 – TCP
  • RFC 826 – ARP
  • RFC 854 – Telnet
  • RFC 951 – Bootstrap Protocol (BOOTP)
  • RFC 959 – FTP
  • RFC 1112 – IP Multicast and IGMP
  • RFC 1157 – SNMP v1
  • RFC 1166 – IP Addresses
  • RFC 1256 – Internet Control Message Protocol (ICMP) Router Discovery
  • RFC 1305 – NTP
  • RFC 1492 – TACACS+
  • RFC 1493 – Bridge MIB
  • RFC 1542 – BOOTP extensions
  • RFC 1643 – Ethernet Interface MIB
  • RFC 1757 – RMON
  • RFC 1901 – SNMP v2C
  • RFC 1902-1907 – SNMP v2
  • RFC 1981 – Path MTU Discovery for IPv6
  • FRC 2068 – HTTP
  • RFC 2131 – DHCP
  • RFC 2138 – RADIUS
  • RFC 2233 – IF MIB v3
  • RFC 2373 – IPv6 Aggregatable Addrs
  • RFC 2460 – IPv6
  • RFC 2461 – IPv6 Neighbor Discovery
  • RFC 2462 – IPv6 Autoconfiguration
  • RFC 2463 – ICMP IPv6
  • RFC 2474 – Differentiated Services (DiffServ) Precedence
  • RFC 2597 – Assured Forwarding
  • RFC 2598 – Expedited Forwarding
  • RFC 2571 – SNMP Management
  • RFC 3046 – DHCP Relay Agent Information Option
  • RFC 3376 – IGMP v3
  • RFC 3580 – 802.1X RADIUS
 
Voltage and Power Ratings
Voltage (Autoranging) 100 to 240 VAC  
Current (Amperes) 0.6 – 0.3  
Frequency 50 to 60Hz  
Power Rating (kVA) 0.04  
DC Input Voltages (RPS Input) 3A at 12V  
Power Consumption 0% traffic: 29.9

10% traffic: 29.7

100% traffic: 30.2

ATIS weighted average: 29.8

 
Safety and Compliance
Regulatory Compliance Products should comply with CE Marking per directives 2004/108/EC and 2006/95/EC  
Safety UL 60950-1 Second Edition

CAN/CSA-C22.2 No. 60950-1 Second Edition

EN 60950-1 Second Edition

IEC 60950-1 Second Edition

AS/NZS 60950-1

 
EMC – Emissions 47CFR Part 15 (CFR 47) Class A

AS/NZS CISPR22 Class A

CISPR22 Class A

EN55022 Class A

ICES003 Class A

VCCI Class A

EN61000-3-2

EN61000-3-3

KN22 Class A

CNS13438 Class A

 
EMC – Immunity EN55024

CISPR24

EN300386

KN24

 
Environmental Reduction of Hazardous Substances (RoHS) including Directive

Bình luận / Đánh giá sản phẩm

Sản phẩm liên quan

SWITCH CISCO WS-C2960+48TC-S

Giá bán: Liên Hệ
Mua ngay
Thêm vào giỏ

Đăng ký nhận tin

Hãy để địa chỉ email của bạn để nhận thông tin mới nhất từ chúng tôi.

Hình thức thanh toán

  • logo

    Chào bạn!

  • logo

    Bạn cần Shop tự vấn hoặc hỗ trợ thêm thông tin gì không bạn ha?

product_detail